Product info - China Gate Company
 
Category
Physiology Teaching Kit
P-V loop
Blood Pressure and ECG
Pain and Inflammation
Body Composition
Zebrafish
Isolated Heart Perfusion
Isolated Tissue Perfusion
Optogenetics
Non-invasive Blood Flow Velocity Measurement
Small Animal Surgical Monitoring
Tissue Organ Bath System
Data Recorder and Amplifier
Wire Myograph Systems
Transducers/Electrodes/accessories
Muscle Strip Myograph System
Culture Myograph Systems
Pressure Myograph System
Hypoxia Workstation
Colony Counting
Tissue Vitality Monitoring
Motory Coordination, Grip Strength, Activity
Animal Metabolic MeasureMent
MISCELLANEOUS, ECT, LMD
TISSUE BATHS, TRANSDUCERS, RECORDERS
METABOLISM, FEEDING BEHAVIOUR
BEHAVIOUR
Ventilation, Anesthesia, Surgical Monitoring
BLOOD PRESSURE, VITAL FUNCTIONS
Product Info

6 lead ECG

This system includes the IX-228S 10- channel recorder with 2 dedicated biopotential channels and 8 additional transducer inputs. The 2 biopotential input channels have software configurable gains and high-pass and low-pass filter settings. This system allows for simultaneous recording of 6 ECG leads (lead I and lead II are measured, lead III, aVR, aVL and aVF are calculated). 6 lead ECG
   

  Features Specification Other info  
Resolution and Noise
The high resolution of the iWorx 300 series recorders combined with an unparalleled signal-to-noise ratio (noise as low as 32 microvolts) make it possible to resolve even the most subtle changes in pressure, tension, temperature, or other research parameters. For example, in vascular tissue studies, tension as low as 1 mg can be measured reliably. Likewise, changes as low as 0.1° C during thermal studies, or pressure changes as low as 0.1 mmHg during vascular studies, can easily be resolved.
Analog Outputs
Each channel of the iWorx 300 series recorders is equipped with an independently programmable 16 bit, +/-10V stimulator (DAC). Parameters for each stimulator, such as pulse width, frequency and amplitude, may be changed “on-the-fly” using handy controls located in the LabScribe2™ software tool bar. Standard protocols include Pulse, Train, Step, Triangle and Ramp. Each standard protocol allows the quiescent state to be a holding voltage, thereby making it ideal for voltage clamping applications.
Digital Output
Eight digital outputs are available to control devices such as pumps and valves. Programming the output lines is point-and-click easy, with no complicated scripting language required.
Speed
These recorders have a maximum sampling speed of 5 kHz on each channel, more than fast enough for the applications for which they are intended. 