Product info - China Gate Company
 
Apply
Data Recorder
Physiology Teaching Kit
ECG
P-V loop
Blood Pressure
Allodynia,Hypersensitivity,Somatosensation
Blood Flow Meter
Telemetry
Animal Surgical Heating
Stimulator
Breath and Gas analysis
Neuropathic Pain, Hyperalgesia, Inflammation, Joint Pain (Arthritis)
Animal Experiment
Non-invasive ECG Measurement
Small Animal Surgical Monitor
Small Animal Surgical Monitor
Blood Flow Velocity Measurement
Electrophysiology
Working Heart
Langendorff
Heart Perfusion
Zebrafish Research
Body Composition
Bioelectricity Detection
Blood Oxygen Saturation
Atheroscleosis
Erectile dysfunction
Gut research
Gall bladder research
Urinary and bladder research
Intestine research
Airway research
Vascular Research
Data acquisition and analysis
Cardiac Diseases
Vascular research
Diabetes
Lymphatic transport
Cardiac research
Skeletal Muscle research
Metabolism
Amplifier
Hypertension
Hypoxia Workstation
Colony Counting
Tissue Vitality Monitoring
Animal Metabolic MeasureMent
EPILEPSY, SEIZURES, CONVULSIONS (ECT)
ELECTROLYTIC LESIONS AND INFUSION
Addiction and Reward, Social Behaviour and Autism
Memory, Learning, Alzheimer
VENTILATION, ANESTHESIA, SURGICAL MONITORING
Motor Function, Parkinson’s, Strength, Exercise
Anxiety, Depression, Fear, Stress
Product Info

ETH-3100

The iWorx ETH-3100 Intracellular Electrometer is a simple to use, low cost intracellular amplifier. It comes equipped with a small and light weight probe measuring 1.1cm in diameter by 5.6cm long and weighing only 10 grams. The dual-transient control provides extremely precise adjustments to transient suppression during membrane recordings. The DC balance control eliminates the need for an external bridge or a differential input oscilloscope. The DC offset provides electrode offset control up to ±1V. An internal square-wave generator supplies a 100Hz current pulse to determine electrode resistance. It is also useful to adjust capacitance compensation. Capacity compensation can adjust up to 35pF of electrode capacitance. Additional stray capacitance can be reduced by using the driven shield connector on the head stage probe.  ETH-3100
   

  Features Specification Other info  

ETH-3100 Specifications

Noise (10Hz - 50kHz):18µV, rms shorted; < 350µV, 20MΩ source 

Input impedance:1013Ω; capacitance adjustable to zero

Bias current:Adjustable to zero 

Voltage gain:x1 and x10 

Capacity compensation:- 4pF - 35pF

DC Offset:±1V 

Max internal current:1µA External current:

100nA/V; 10V maximum 

Electrode test:100Hz, 10 nA; (i.e. 10mV/MΩ electrode resistance)

Ringer:0 - 10V biphasic, 2 - 8kHz 

Power:External power supply for low noise



Related Products
Thisrugged,reliable,four
TheiWorx228SDataAcquisit
12-leadECG ThisECGreco
TheNA-200NeuroampExtrace
TheNA-100isoptimizedforh
iWorx400seriesareeconomi
Thisrugged,reliable,four
TheETH-402isadedicatedam
TheETH-401isadedicatedbr
TheETH-256isahighperform
iWorxprovidestransduce
TheiWorx300SeriesRecorde