Product info - China Gate Company
 
Apply
Data Recorder
Physiology Teaching Kit
ECG
P-V loop
Blood Pressure
Allodynia,Hypersensitivity,Somatosensation
Blood Flow Meter
Telemetry
Animal Surgical Heating
Stimulator
Breath and Gas analysis
Neuropathic Pain, Hyperalgesia, Inflammation, Joint Pain (Arthritis)
Animal Experiment
Non-invasive ECG Measurement
Small Animal Surgical Monitor
Small Animal Surgical Monitor
Blood Flow Velocity Measurement
Electrophysiology
Working Heart
Langendorff
Heart Perfusion
Zebrafish Research
Body Composition
Bioelectricity Detection
Blood Oxygen Saturation
Atheroscleosis
Erectile dysfunction
Gut research
Gall bladder research
Urinary and bladder research
Intestine research
Airway research
Vascular Research
Data acquisition and analysis
Cardiac Diseases
Vascular research
Diabetes
Lymphatic transport
Cardiac research
Skeletal Muscle research
Metabolism
Amplifier
Hypertension
Hypoxia Workstation
Colony Counting
Tissue Vitality Monitoring
Animal Metabolic MeasureMent
EPILEPSY, SEIZURES, CONVULSIONS (ECT)
ELECTROLYTIC LESIONS AND INFUSION
Addiction and Reward, Social Behaviour and Autism
Memory, Learning, Alzheimer
VENTILATION, ANESTHESIA, SURGICAL MONITORING
Motor Function, Parkinson’s, Strength, Exercise
Anxiety, Depression, Fear, Stress
Product Info

ETH-256C

The ETH-256 is a high performance general-purpose life science research amplifier. Its high input impedance and high CMR allows low noise recording of biopotential signals, as well as outputs from strain gauge type transducers, such as force, displacement and pressure. The optional C-ISO-256 isolated head stage may be used with the ETH-256 for recording ECG, EMG and EEG signals from humans. ETH-256C
   

  Features Specification Other info  

The ETH-256 is a high performance general-purpose life science research amplifier. Its high input impedance and high CMR allows low noise recording of biopotential signals, as well as outputs from strain gauge type transducers, such as force, displacement and pressure. The optional C-ISO-256 isolated head stage may be used with the ETH-256 for recording ECG, EMG and EEG signals from humans.

Each channel can provide +/-5.0V of excitation at 50 mA, adequate for most commonly used transducers. In addition, customers may specify adapter cables to accommodate Grass, Gould or HP sensors. The ETH-256 offers eight gain settings, x1, x5, x10, x50, x100, x500, x1k and x5k. Signals may be further conditioned using high and low pass frequency filters.All filters are four pole active design with sharp roll offs. High pass filter cuts, useful for biopotential measurements, are available at DC, 0.03 Hz, 0.3 Hz and 3 Hz.Low pass filters, useful for limiting high frequency noise, are available at 5 Hz, 50 Hz, 150 Hz, 2 kHz and 10 kHz.

Either of the ETH-256 amplifier's channels may be configured as a bridge-style transducer amplifier or as a biopotential amplifier. In bridge mode the ETH 256 amplifier's 10 gigOhm input impedance and differential input allow it to accept input from force, displacement or pressure transducers. In addition, input from many thermistors, pH electrodes and other variable resistance devices is possible. In the biopotential mode, the ETH-256 functions as a low noise AC coupled preamplifier.


Related Products
Thisrugged,reliable,four
TheiWorx228SDataAcquisit
12-leadECG ThisECGreco
TheNA-200NeuroampExtrace
TheNA-100isoptimizedforh
iWorx400seriesareeconomi
Thisrugged,reliable,four
TheETH-402isadedicatedam
TheETH-401isadedicatedbr
TheiWorxETH-3100Intracel
iWorxprovidestransduce
TheiWorx300SeriesRecorde